HIGH-STABILITY CURRENT CONTROL IN THE 10 A RANGE

Authors
Citation
E. Rubiola, HIGH-STABILITY CURRENT CONTROL IN THE 10 A RANGE, IEEE transactions on instrumentation and measurement, 45(5), 1996, pp. 865-871
Citations number
11
Categorie Soggetti
Engineering, Eletrical & Electronic","Instument & Instrumentation
ISSN journal
00189456
Volume
45
Issue
5
Year of publication
1996
Pages
865 - 871
Database
ISI
SICI code
0018-9456(1996)45:5<865:HCCIT1>2.0.ZU;2-P
Abstract
This paper reports on the design and evaluation of a high-stability cu rrent control developed for energizing the C-field magnet of the high- field cesium standard experiment, currently in progress at the Politec nico di Torino. This source must supply about 0.8 kW de power with a c urrent stability in the 10(-7) range for more than 1 h.