ACCURACY OF THE SINGLE-ELECTRON PUMP USING AN OPTIMIZED STEP-LIKE RF DRIVE WAVE-FORM

Citation
Lrc. Fonseca et al., ACCURACY OF THE SINGLE-ELECTRON PUMP USING AN OPTIMIZED STEP-LIKE RF DRIVE WAVE-FORM, Applied physics letters, 69(13), 1996, pp. 1858-1860
Citations number
12
Categorie Soggetti
Physics, Applied
Journal title
ISSN journal
00036951
Volume
69
Issue
13
Year of publication
1996
Pages
1858 - 1860
Database
ISI
SICI code
0003-6951(1996)69:13<1858:AOTSPU>2.0.ZU;2-J
Abstract
We have performed an optimization of those parameters of a single-elec tron pump that may influence the accuracy of this device as a standard of de current. Two types of rf drive were considered: the traditional triangular waveform and a step-like waveform. We have shown that, aft er optimization, the accuracy of the pump may be improved considerably in a wide range of drive frequencies, especially at low temperatures, using the step-like waveform. For example, the error of a five-juncti on pump with junction capacitances C = 0.1 fF at 100 mK and 10 MHz may be as small as 10(-13). (C) 1996 American Institute of Physics.