Qb. Jiang et al., HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF MIDAZOLAM INRAT-BRAIN, Journal of chromatography B. Biomedical applications, 683(2), 1996, pp. 276-280
Citations number
14
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
Journal title
Journal of chromatography B. Biomedical applications
A high-performance liquid chromatography method for the determination
of midazolam in rat brain is described. Midazolam and the internal sta
ndard halazepam were extracted with toluene and analyzed isocratically
on a reversed-phase column with a mobile phase consisting of methanol
, acetonitrile and potassium phosphate buffer. Detection was monitored
by ultraviolet absorption at 240 nm. The standard curves were linear
over the range of 25-350 ng midazolam per 50 mg brain tissue. The day-
to-day coefficient of variation ranged from 1.7 to 6.9%. The limit of
quantification was 80 ng/g brain tissue. The method is rapid, simple a
nd reproducible for brain analysis.