EXCESS-ENTHALPIES FOR THE SYSTEMS 1,3-BUTANEDIOL PLUS CYCLOHEXANOL PLUS DECANE AND 1,2-PROPANEDIOL PLUS 1,3-BUTANEDIOL PLUS CYCLOHEXANOL AND FOR CONSTITUENT BINARIES AT 318.15 K
M. Kuus et al., EXCESS-ENTHALPIES FOR THE SYSTEMS 1,3-BUTANEDIOL PLUS CYCLOHEXANOL PLUS DECANE AND 1,2-PROPANEDIOL PLUS 1,3-BUTANEDIOL PLUS CYCLOHEXANOL AND FOR CONSTITUENT BINARIES AT 318.15 K, Journal of chemical and engineering data, 41(5), 1996, pp. 1206-1209
Excess enthalpies (H-E) were determined for two ternary systems, 1,3-b
utanediol + cyclohexanol + decane and 1,2-propanediol + 1,3-butanediol
+ cyclohexanol, and for their five constituent binaries at 318.15 K w
ith a Calvet-type microcalorimeter. The ternary liquid-liquid coexiste
nce curve for the first ternary system was measured at 318.15 K by the
titration method. From the experimental results for binary systems, p
arameters of the Redlich-Kister equation were obtained and used to pre
dict the ternary H-E results.