Md. Johns et al., A POSITIVE APPROACH TO GROUTING, Proceedings of the Institution of Civil Engineers. Structures and buildings, 110(4), 1995, pp. 398-409
Citations number
9
Categorie Soggetti
Engineering, Civil","Construcion & Building Technology
This paper describes the successful grouting of prestressing tendons o
n Taff Viaduct, part of the Butetown Link Road in Cardiff. Discussion
of the grout's performance shows the relationship of water/cement rati
o, admixtures and temperature to bleed, shrinkage and flow, Also, the
practical problems associated with grouting of discontinuous internal
ducts typical of a segmental structure are highlighted.