Rw. Fedeniuk et al., APPLICATION OF REVERSED-PHASE LIQUID-CHROMATOGRAPHY AND PREPACKED C-18 CARTRIDGES FOR THE ANALYSIS OF OXYTETRACYCLINE AND RELATED-COMPOUNDS, Journal of chromatography B. Biomedical applications, 677(2), 1996, pp. 291-297
Citations number
20
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
Journal title
Journal of chromatography B. Biomedical applications
The reversed-phase (RP) chromatographic separation of oxytetracycline
(OTC) 4-epioxytetracycline (4-epiOTC), alpha-apooxytetracycline (alpha
-apoOTC), and beta-apooxytetracycline (beta-apoOTC) has been accomplis
hed on an Inertsil C-8 column at ambient temperature; Using the simple
x method of solvent optimization, a 0.1 M ammonium acetate buffer (pH
3.0)-acetonitrile-tetrahydrofuran (72.5:12.5:15, v/v/v) mobile phase w
as found to give excellent separation of the compounds. OTC, 4-epiOTC,
alpha-apoOTC and beta-apoOTC were resolved in 35 min with calculated
detection limits of 40, 20, 50 and 140 ng/ml, respectively. Solid-phas
e extraction (using RP C-18 cartridges) of OTC and OTC degradation com
pounds from distilled water and porcine muscle was tested at four conc
entration levels ranging from 200 to 2000 ng/ml (g); overall mean reco
very of OTC from distilled water and porcine tissue was greater than 9
0% and 70%, respectively.