Background In cataract surgery high quality is demanded. That is why h
igh precision in calculation of IOL power is necessary for predicting
postoperative refraction. Materials and Methods In a series of 103 pat
ients the predicted refraction - calculated by the SRK II formula for
only one type of IOL (A-constant 118,9) - was compared to the recieved
early and late (3 month) postoperative refraction. Results The accura
cy of IOL calculations in 95% was acceptable - within a range of 2 dio
pters. The prediction errors of extender values were only shown in cas
es of axial length of more than 26 millimeters. Conclusions The result
s confirm the fact that by means of SRK II formula the accuracy of IOL
calculation is satisfactory in respect of predicted refraktion. In ey
es of elongated axial length the accuracy is limited.