PARTIAL NEPHRECTOMY PERFORMED WITH LINEAR STAPLING DEVICE - AN EXPERIMENTAL-STUDY

Authors
Citation
J. Baniel et M. Schein, PARTIAL NEPHRECTOMY PERFORMED WITH LINEAR STAPLING DEVICE - AN EXPERIMENTAL-STUDY, Scandinavian journal of urology and nephrology, 30(4), 1996, pp. 253-255
Citations number
7
Categorie Soggetti
Urology & Nephrology
ISSN journal
00365599
Volume
30
Issue
4
Year of publication
1996
Pages
253 - 255
Database
ISI
SICI code
0036-5599(1996)30:4<253:PNPWLS>2.0.ZU;2-O
Abstract
The use of linear stapling devices for partial resection of parenchyma tous organs is not widely known. We have successfully employed this me thod for partial nephrectomy. A study in dogs is reported, and the adv antages, indications and various technical aspects are discussed.