The coupling of the pre-stressed thermal insulated tubing string broke
down inside the steam flooding welts, after the tubing were used in h
igh temperature and high pressure steam for about two years. With furt
her check, it was found that most of the weld joints between the inner
and outer tubing also cracked. The failure analysis for the accidents
has been carried out by the analysis of chemical composition for the
steels, microstructure observation, mechanical property tests, and the
investigation of the service environment etc.. The results show that
the early damage of the pre-stressed thermal insulated tubing string i
s mainly induced by the caustic stress corrosion, which can be strengt
hened by an unstable microstructure of the coupling serviced at high t
emperature for a long time. Moreover, the high pre-stress design on th
e thermal insulated pipe for the cyclic steam injection may be not sui
table to the situation of steam flooding, which would result in the we
ld joint cracking.