M. Trzebiatowska et al., EFFECTS OF PH ON THE ULTRAFILTRATION OF BOVINE SERUM-ALBUMIN AT HIGH IONIC-STRENGTH USING A MACROPOROUS TITANIA MEMBRANE, Journal of food process engineering, 19(4), 1996, pp. 469-478
The ultrafiltration of bovine serum albumin (BSA) buffered at pH 3.8,
4.8 and 6.8 in solutions with ionic strengths greater than 0.05 mol dm
(3) was investigated at pressures of 0.20 and 0.70 MPa using a macropo
rous titania membrane. Protein rejections as high. as 0.94 were obtain
ed. Both pH ana pressure affected the permeability and rejection. The
relative amount of irreversible fouling was estimated by evaluating pa
rameters of a resistance model. Conditions providing the lowest foulin
g index and the least irreversible fouling while retaining high BSA re
jection were obtained at the highest pH, 6.8, and lowest pressure, 0.2
0 MPa.