Jr. Fu et Ta. Lipo, A STRATEGY TO ISOLATE A SWITCHING DEVICE FAULT IN A CURRENT REGULATEDMOTOR DRIVE, Electric machines and power systems, 24(8), 1996, pp. 911-920
In this paper a new, improved induction motor control topology is prop
osed which allows for continuous, disturbance-free operation of the dr
ive with a failed short-circuited switch in one leg of the inverter. T
he analysis of this control strategy and the computer simulation are e
xplored. The experimental results from hardware are attached to verify
the simulation results. A complete control strategy combined with sho
rt-circuit fault and open-circuit fault is also included.