Ajh. Maas et al., RECOIL SELECTION BY PULSE-SHAPE DISCRIMINATION IN ELASTIC RECOIL DETECTION ANALYSIS WITH ALPHA-PARTICLES (ALPHA-ERDA), Nuclear instruments & methods in physics research. Section B, Beam interactions with materials and atoms, 118(1-4), 1996, pp. 268-273
In elastic recoil detection analysis (ERDA) with alpha-particles, reco
ils can be separated from scattered projectiles by using detectors wit
h a thin depletion layer and a pulse shape discrimination (PSD) circui
t [S.S. Klein and H.A. Rijken, Nucl. Instr. and Meth. B 66 (1992) 393]
. Improved performance is obtained with a multi-parameter data acquisi
tion system; recoil events are more easily and accurately selected and
sensitivity is improved by a factor of 5 to 1 X 10(14) at/cm(2) for o
xygen on amorphous silicon. The typical surface depth resolution is 10
nm. Two alternative PSD circuits are proposed neither of them using f
ast electronics. Examples are given of profiling carbon and oxygen in
thin films of Si, C and SiOxNy.