Ag. Sherif et Wh. Dilger, CRITICAL-REVIEW OF THE CSA A23.3-94 PUNCHING SHEAR-STRENGTH PROVISIONS FOR INTERIOR COLUMNS, Canadian journal of civil engineering, 23(5), 1996, pp. 998-1011
The purpose of this paper is to demonstrate that the shear design of s
labs according to the relevant Canadian CSA A23.3-94 (and U.S. ACI 318
-95) design codes can be unsafe under certain conditions, and to propo
se improved design equations, some of which should be considered immed
iately for implementation in the Canadian CSA code. The paper deals wi
th interior slab-column connections, with and without shear reinforcem
ent, subjected to shear force alone or to a combination of shear force
and unbalanced bending moment. Some comparisons with the British code
BS 8110-85 and the CEB-FIP model code 1990 are also made. Tests repor
ted in the literature and some experiments by the authors provide the
basis for this study.