IMPROVING THE CALIBRATION OF DIELECTRIC TDR SOIL-MOISTURE DETERMINATION TAKING INTO ACCOUNT THE SOLID SOIL

Citation
Ma. Malicki et al., IMPROVING THE CALIBRATION OF DIELECTRIC TDR SOIL-MOISTURE DETERMINATION TAKING INTO ACCOUNT THE SOLID SOIL, European journal of soil science, 47(3), 1996, pp. 357-366
Citations number
16
Categorie Soggetti
Agriculture Soil Science
ISSN journal
13510754
Volume
47
Issue
3
Year of publication
1996
Pages
357 - 366
Database
ISI
SICI code
1351-0754(1996)47:3<357:ITCODT>2.0.ZU;2-0
Abstract
The influence of soil's solid phase on the dielectric constant of the soil over a range of moisture contents has been studied. Samples of so il, soil-like, and also other porous materials were analysed using Tim e Domain Reflectometry (TDR) to determine the contribution of bulk den sity and porosity to the function that relates dielectric constant to water content. The study showed that bulk density, and thus also poros ity, substantially affects the relation between dielectric constant an d water content. Two equivalent, empirical, normalized conversion func tions were found, one accounting for bulk density and the other for po rosity. Each of them reduced the root mean square error of the dielect ric TDR determinations of moisture to 0.03, regardless of the material 's bulk density and porosity.