A MODIFICATION OF SINGLE STAPLED COLORECTAL ANASTOMOSIS USING THE TRANSANAL INSERTION DEVICE (TAIS)

Citation
Dc. Hoffmann et al., A MODIFICATION OF SINGLE STAPLED COLORECTAL ANASTOMOSIS USING THE TRANSANAL INSERTION DEVICE (TAIS), Australian and New Zealand journal of surgery, 66(11), 1996, pp. 768-769
Citations number
1
Categorie Soggetti
Surgery
ISSN journal
00048682
Volume
66
Issue
11
Year of publication
1996
Pages
768 - 769
Database
ISI
SICI code
0004-8682(1996)66:11<768:AMOSSC>2.0.ZU;2-0
Abstract
A modification of single stapled colorectal anastomosis utilizing a re usable stapler head (transanal insertion device [TAIS]) is described. This modification minimizes the time that the proximal bowel is open b y allowing early placement of the circular stapler head, and minimizes the risk of rectal injury that may be associated with the passage of a circular stapling device without the head in situ.