CALCULATIONS OF GIANT MAGNETOIMPEDANCE AND OF FERROMAGNETIC-RESONANCERESPONSE ARE RIGOROUSLY EQUIVALENT

Citation
A. Yelon et al., CALCULATIONS OF GIANT MAGNETOIMPEDANCE AND OF FERROMAGNETIC-RESONANCERESPONSE ARE RIGOROUSLY EQUIVALENT, Applied physics letters, 69(20), 1996, pp. 3084-3085
Citations number
28
Categorie Soggetti
Physics, Applied
Journal title
ISSN journal
00036951
Volume
69
Issue
20
Year of publication
1996
Pages
3084 - 3085
Database
ISI
SICI code
0003-6951(1996)69:20<3084:COGMAO>2.0.ZU;2-C
Abstract
It is simply demonstrated that the giant magnetoimpedance (GMI) respon se of a plate or ribbon is rigorously equivalent to the response of th e same sample in ferromagnetic resonance (FMR) experiment. Thus, all o f the solutions for FMR response behavior of metals may be applied to the description of GMI. For situations which have not been studied bef ore, the methods which have been developed over the past 40 years for theoretical description of FMR in metals may be applied to predict the GMI behavior. (C) 1996 American Institute of Physics.