CRITICAL-POINT MEASUREMENTS FOR 14 COMPOUNDS BY A STATIC METHOD AND AFLOW METHOD

Citation
Lc. Wilson et al., CRITICAL-POINT MEASUREMENTS FOR 14 COMPOUNDS BY A STATIC METHOD AND AFLOW METHOD, Journal of chemical and engineering data, 41(6), 1996, pp. 1252-1254
Citations number
5
Categorie Soggetti
Engineering, Chemical",Chemistry
ISSN journal
00219568
Volume
41
Issue
6
Year of publication
1996
Pages
1252 - 1254
Database
ISI
SICI code
0021-9568(1996)41:6<1252:CMF1CB>2.0.ZU;2-S
Abstract
A static method was used to measure the critical temperature, critical pressure, and critical volume on three compounds: ethyl thioacetate, methoxybenzene, and 2-methoxyethanol. A flow method was used to measur e the critical temperature and critical pressure on eleven compounds: acrylonitrile, 1,4-butanediol, 2-(2-butoxyethoxy)ethyl acetate, gamma- butyrolactone, cyclohexanol, 1,2-ethanediamine, 2-(2-ethoxyethoxy)etha nol, 2-(2-ethoxyethoxy)ethyl acetate, 1-methoxy-2-propanol, 2-(2-metho xyethoxy)ethanol, and 2-nonanone.