H. Ikeda et al., POWER-SUPPLY GROUND-RIPPLE REJECTION CAPABILITY OF THE SMA(2)SH PREAMPLIFIER ARRAY FOR A SILICON MICRO-STRIP DETECTOR/, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 381(1), 1996, pp. 178-180
The noise characteristic of the SMA(2)SH-series preamplifier array has
been updated in terms of its sensitivity to external disturbances. An
eight-channel version of the SMA(2)SH preamplifier was employed for t
he evaluation. In order to distinguish a power-supply disturbance from
that coming from ground, we employed two configurations of an interna
l biasing circuit for the preamplifier, We ultimately found a scheme t
o eliminate external disturbances, where we obtained a noise level of
1000 electrons al 30 pF of the detector capacitance with a noise slope
of 20 electrons/pF.