A 2-DIMENSIONAL NUMERICAL INVESTIGATION OF THE OPTIMAL REMOVAL TIME AND ENTROPY PRODUCTION-RATE FOR A SENSIBLE THERMAL STORAGE-SYSTEM

Citation
Jg. Maveety et A. Razani, A 2-DIMENSIONAL NUMERICAL INVESTIGATION OF THE OPTIMAL REMOVAL TIME AND ENTROPY PRODUCTION-RATE FOR A SENSIBLE THERMAL STORAGE-SYSTEM, Energy, 21(12), 1996, pp. 1265-1276
Citations number
15
Categorie Soggetti
Energy & Fuels","Engineering, Chemical
Journal title
EnergyACNP
ISSN journal
03605442
Volume
21
Issue
12
Year of publication
1996
Pages
1265 - 1276
Database
ISI
SICI code
0360-5442(1996)21:12<1265:A2NIOT>2.0.ZU;2-A
Abstract
We extend a previous one-dimensional analytical study to consider two- dimensional transient effects of a cylindrical, sensible energy-storag e system. The working fluid NaK is assumed to be incompressible. Energ y transfer from the high temperature surrounding domain is due to cond uction in the annulus and convection to the working fluid. We apply a two-dimensional, explicit numerical scheme to quantify transient tempe rature profiles within the two domains. In addition we consider second law aspects of the two subsystems and isolate irreversibilities which reduce the availability. Finally, we exploit the normalized figure of merit which characterizes the optimal ratio of exergy extraction to t he total exergy change of the thermal storage system as a function of removal time. Copyright (C) 1996 Elsevier Science Ltd.