K. Matsui et al., DIRECT DETERMINATION OF E2020 ENANTIOMERS IN PLASMA BY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY AND COLUMN-SWITCHING TECHNIQUES, Journal of chromatography, 694(1), 1995, pp. 209-218
High-performance liquid chromatography with column switching and mass
spectrometry (MS) was applied to the on-line determination and resolut
ion of the enantiomers of E2020 (acetylcholinesterase inhibitor) in pl
asma. This system employs two avidin columns and fast atom bombardment
(FAB)-MS. A plasma sample was injected directly into an avidin trappi
ng column (10 mm x 4.0 mm I.D.). The plasma protein was washed out fro
m the trapping column immediately while E2020 was retained. After the
column-switching procedure, E2020 was separated enantioselectivity in
an avidin analytical column. The separated E2020 enantiomers were spec
ifically detected by FAB-MS without interference from metabolites of E
2020 and plasma constituents. The limit of quantification for each ena
ntiomer of E2020 in plasma was 1.0 ng/ml and the intra- and inter-assa
y relative standard deviations for the method were less than 5.2%. The
assay was validated for enantioselective pharmacokinetic studies in t
he dog.