Details are presented of art experimental and theoretical investigatio
n of the defect sizing capabilities of the transient thermography tech
nique. Back-drilled hole artificial defects, of diameters from 2 to 10
mm and at depths between 0.5 and 1.7 mm, in bakelite plates, were the
rmographically imaged. Full-width at half maximum (FWHM) of a defect i
mage is shown to be accurately related to defect diameter These measur
ements are also shown to be in excellent agreement with finite-differe
nce simulations of the response of this type of defect. The temporal d
ependences of the images are shown to provide an indication of defect
depth.