AIR SIDE PERFORMANCE OF BRAZED ALUMINUM HEAT-EXCHANGERS

Authors
Citation
Yj. Chang et Cc. Wang, AIR SIDE PERFORMANCE OF BRAZED ALUMINUM HEAT-EXCHANGERS, Journal of enhanced heat transfer, 3(1), 1996, pp. 15-28
Citations number
17
Categorie Soggetti
Thermodynamics,"Engineering, Mechanical
ISSN journal
10655131
Volume
3
Issue
1
Year of publication
1996
Pages
15 - 28
Database
ISI
SICI code
1065-5131(1996)3:1<15:ASPOBA>2.0.ZU;2-2
Abstract
Extensive experiments on the heat transfer and pressure drop character istics of brazed aluminum heat exchangers were carried out. In the pre sent study, 27 samples of louvered fin heat exchangers with different geometrical parameters, including tube width, louver length, louver pi tch, fin height, and fin pitch were tested in an induced draft open wi nd tunnel. Results are presented as plots of friction factor, f, and C olburn j factor against Reynolds number based on louver pitch in the r ange of 100 to 1000. Comparisons between the Sahnoun and Webb model an d the present test data are reported and good agreements were found. B y introducing ''area ratio'' parameters, a simpler correlation of the Colburn j factor and friction factor f were obtained. It is shown thar 85% of the experimental data of heat transfer and friction data were correlated within +/-10%.