Abstract
The body temperatures of infants weighing less than 1500 g under radia nt warmers during routine care were documented in the first week of li fe. Ten infants (median gestational age 28 weeks, median birthweight 9 13 g) were studied, During 30 nursing interventions (mean 9.2 minutes) mean oesophageal and foot temperature changed 0 degrees C and -0.11 d egrees C, respectively. A radiant warmer may limit heat loss during in terventions because of easy access and rapid radiant warmer responsive ness.