PERCUTANEOUS ENDOLUMINAL STENT GRAFT REPAIR OF AN OLD TRAUMATIC FEMORAL ARTERIOVENOUS-FISTULA

Citation
R. Uflacker et Bm. Elliott, PERCUTANEOUS ENDOLUMINAL STENT GRAFT REPAIR OF AN OLD TRAUMATIC FEMORAL ARTERIOVENOUS-FISTULA, Cardiovascular and interventional radiology, 19(2), 1996, pp. 120-122
Citations number
7
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
ISSN journal
01741551
Volume
19
Issue
2
Year of publication
1996
Pages
120 - 122
Database
ISI
SICI code
0174-1551(1996)19:2<120:PESGRO>2.0.ZU;2-Y
Abstract
A stent-graft was custom made to close a high-flow traumatic arteriove nous fistula of the left superficial femoral artery, present for 30 ye ars, in a 60-year-old man with congestive heart failure and ischemic u lceration in the left foot, A balloon expandable Palmaz stent (P394; 2 .5 mm X 3.9 cm) was covered with a polytetrafluoroethylene (PTFE) graf t and was inserted percutaneously through an 11 Fr vascular sheath. Fo llow-up Doppler ultrasound at 6 months demonstrated occlusion of the a rteriovenous fistula, patency of the artery, and luminal integrity of the artery and vein.