Sa. Ashour et Rd. Hanson, EFFECT OF ADDED DAMPERS ON THE SEISMIC RESPONSE OF MULTISTORY BUILDINGS, Arabian journal for science and engineering, 19(3), 1994, pp. 389-402
The consequences of adding supplemental damping in buildings were inve
stigated. The analysis included response determinations and energy com
ponent evaluations. The reliability of modal superposition was studied
by considering the effects of damping nonproportionality. Four proced
ures were proposed to calculate the response of a structure having sup
plemental damping and alternative patterns of damper installation to i
ncrease the efficiency of the damper in reducing the response were con
sidered. An example ten-story building was used to illustrate these an
alyses and the feasibility of introducing supplemental damping in stru
ctures.