S. Krishnan et al., THE ADHESION-INDUCED DEFORMATION AND THE REMOVAL OF SUBMICROMETER PARTICLES, Journal of adhesion science and technology, 8(11), 1994, pp. 1357-1370
Adhesion-induced deformations of submicrometer polystyrene particles o
n silicon substrates were observed as a function of time using scannin
g electron microscopy. The contact area between the particle and the s
ubstrate was found to increase with time for a period of approximately
72 hours before reaching a constant value. The ratio of the final con
tact radius to the particle radius was almost-equal-to 0.4. The time d
ependence of this deformation appears similar to the creep phenomenon
in bulk polymers. These results are related to the studies of particle
removal conducted for different time periods, using hydrodynamic and
centrifugal removal forces. The removal efficiency was found to decrea
se with time. This correlates well with the increase in the adhesion f
orce on the particles with time as observed from the SEM measurements.
The effect of the particle diameter on the removal efficiency and the
correlation between the time dependent adhesion-induced deformation a
nd particle removal efficiency is discussed.