M. Chmielowski et A. Witek, TUNNELING THERMOMETER, Sensors and actuators. A, Physical, 45(2), 1994, pp. 145-151
Citations number
29
Categorie Soggetti
Engineering, Eletrical & Electronic","Instument & Instrumentation
ISSN journal
09244247
Volume
45
Issue
2
Year of publication
1994
Pages
145 - 151
Database
ISI
SICI code
0924-4247(1994)45:2<145:TT>2.0.ZU;2-B
Abstract
A design is presented for a tunneling thermometer that will not requir e calibration to temperature standards (ITS-90), but can be directly c alibrated with respect to more convenient and accurate mechanical and time standards (kg, m, Hz). The proposed thermometer converts the ener gy of thermal oscillations of a cantilevered quartz beam of submillime ter size into an electrical signal through tunneling-current modulatio n. The tunneling sensor can operate in the temperature range 200-1300 K with a calibration accuracy of 10(-4)-10(-6) and has a lifetime stab ility of 10(-6)-10(-7) after initial calibration. This thermometer is simply constructed (sensor head, electronic module and computer interf ace) and can be built as a portable or remote-operated unit. It can be applied as a virtually drift-free portable temperature reference.