PHYSIOLOGICAL REQUIREMENTS TO SPECTRAL CH ARACTERISTICS OF CONTACT-LENSES FOR CORRECTION OF APHAKIA IN INFANTS

Citation
Ma. Ostrovsky et al., PHYSIOLOGICAL REQUIREMENTS TO SPECTRAL CH ARACTERISTICS OF CONTACT-LENSES FOR CORRECTION OF APHAKIA IN INFANTS, Vestnik oftal'mologii, 110(3), 1994, pp. 15-17
Citations number
18
Categorie Soggetti
Ophthalmology
Journal title
ISSN journal
0042465X
Volume
110
Issue
3
Year of publication
1994
Pages
15 - 17
Database
ISI
SICI code
0042-465X(1994)110:3<15:PRTSCA>2.0.ZU;2-O
Abstract
Results of studies of penetration through the lens of ultraviolet and short-wave visible radiation ''hazardous'' for the retina necessitate development of a new type of aphakic contact lenses whose spectral cha racteristic should meet spectral characteristics of lenses of various age groups.