ANALYSIS OF AN OPEN TYPE FLAT-PLATE COLLECTOR FOR TANNERY EFFLUENT TREATMENT

Authors
Citation
A. Mani et Ss. Murthy, ANALYSIS OF AN OPEN TYPE FLAT-PLATE COLLECTOR FOR TANNERY EFFLUENT TREATMENT, Energy conversion and management, 35(12), 1994, pp. 1061-1071
Citations number
NO
Categorie Soggetti
Energy & Fuels",Mechanics,"Physics, Nuclear",Thermodynamics
ISSN journal
01968904
Volume
35
Issue
12
Year of publication
1994
Pages
1061 - 1071
Database
ISI
SICI code
0196-8904(1994)35:12<1061:AOAOTF>2.0.ZU;2-#
Abstract
In this paper, analysis of an open type flat plate collector for tanne ry effluent treatment is presented. The effects of parameters like ori entation of collector, film thickness, insolation, ambient temperature and relative humidity on the effluent evaporation rate are studied. I t is found that the collector facing south at an inclination of 12.68 degrees and having a solution film thickness of 5 mm gives maximum yea r round performance. The performance of this open type flat plate coll ector is compared with that of the conventional pond.