Xm. Wang et al., DIFFERENTIAL SCANNING CALORIMETRY OF THE EFFECTS OF TEMPERATURE AND HUMIDITY ON PHENOL-FORMALDEHYDE RESIN CURE, Polymer, 35(26), 1994, pp. 5685-5692
Phenol-formaldehyde (PF) resin is a widely used adhesive in the manufa
cture of wood composites. However, curing behaviour of the resin under
various environmental conditions is not well known. A differential sc
anning calorimeter was employed to characterize the degree of resin cu
re in this study. Resin-impregnated glass cloth samples with varied mo
isture contents (0, 31, 71%) were exposed to an environment of control
led temperature (105, 115, 125, 140 degrees C) and relative humidity (
41, 75, 90%) for a series of time periods (0-20 min). The samples were
next conditioned to different levels of relative humidity (0, 64, 89%
) before being sealed in d.s.c, capsules. The degree of cure of these
partially cured samples was then determined by d.s.c. by measuring the
residual heat of cure. The results show that the degree of resin cure
increased with increasing precure temperature and time. The rate of c
ure increased for dry samples as precure humidity increased. However,
the rate of cure decreased with an increase in the initial moisture co
ntent of samples when precured at 90% relative humidity. The effect of
moisture put into a sample immediately before analysis by d.s.c, on t
he subsequent calculation of resin precure became less significant wit
h increasing precure temperature and degree of resin cure.