At. Lee et al., 3-POINT PHASE-CONTRAST VELOCITY-MEASUREMENTS WITH INCREASED VELOCITY-TO-NOISE RATIO, Magnetic resonance in medicine, 33(1), 1995, pp. 122-126
We describe a technique to increase the velocity-to-noise ratio (VNR)
of phase-contrast magnetic-resonance velocity images based on making t
hree measurements/flow encoding axis rather than the usual two, A phas
e-aliased high first moment data set and a nonaliased low first moment
data set are acquired, and the high-moment data are phase unwrapped u
sing the low-moment data. The VNR of the resulting measurement is give
n by that of the high-moment measurement and increases linearly with t
he first moment. A factor of 4 gain in VNR was observed with only a 50
% increase in scan time. Thus, this method is a much more efficient wa
y to increase VNR than simple averaging.