CLEMENTINE RRELAX SRAM PARTICLE SPECTROMETER

Citation
Mg. Buehler et al., CLEMENTINE RRELAX SRAM PARTICLE SPECTROMETER, IEEE transactions on nuclear science, 41(6), 1994, pp. 2404-2411
Citations number
11
Categorie Soggetti
Nuclear Sciences & Tecnology","Engineering, Eletrical & Electronic
ISSN journal
00189499
Volume
41
Issue
6
Year of publication
1994
Part
1
Pages
2404 - 2411
Database
ISI
SICI code
0018-9499(1994)41:6<2404:CRSPS>2.0.ZU;2-S
Abstract
The Clementine RRELAX radiation monitor chip consists of a p-FET total dose monitor and a 4-kbit SRAM particle spectrometer. Eight of these chips were included in the RRELAX and used to detect the passage of th e Clementine (S/C) and the innerstage adapter (ISA) through the earth' s radiation belts and the 21-Feb 1994 solar flare. This is the first s pace flight for this 1.2-mu m rad-soft custom CMOS radiation monitor. This paper emphasizes results from the SRAM particle detector which sh owed that it (a) has a detection range of five orders of magnitude rel ative to the 21-Feb solar flare; (b) is not affected by electrons, and (c) detected microflares occurring with a 26.5-day period.