REPORT ON SUPPLEMENTARY TYPE TESTING OF P LATE HEAT-EXCHANGERS FOR THE MILK HEATERS H-17 DUO-SAFETY AND N-35 DUO-SAFETY

Citation
Hg. Biewendt et W. Buchheim, REPORT ON SUPPLEMENTARY TYPE TESTING OF P LATE HEAT-EXCHANGERS FOR THE MILK HEATERS H-17 DUO-SAFETY AND N-35 DUO-SAFETY, Kieler Milchwirtschaftliche Forschungsberichte, 46(4), 1994, pp. 329-342
Citations number
NO
Categorie Soggetti
Food Science & Tenology
ISSN journal
00231347
Volume
46
Issue
4
Year of publication
1994
Pages
329 - 342
Database
ISI
SICI code
0023-1347(1994)46:4<329:ROSTTO>2.0.ZU;2-W
Abstract
According to the Milk Ordinance of June 23, 1989 milk heaters must als o be equipped with an appropriate safety device to avoid mixing of the heated milk with insufficiently heated milk. APV-Baker (Kolding, DK), has, therefore, developed twin plate heat exchangers (Duo-Safety). In case of a rupture of the plate the milk flows outside via a pressurel ess interspace, so that further safety precautions will not be necessa ry. The suitability of these novel with twin plates for the purpose ai med at, their stability and their thermic properties have been tested. Positive test results were obtained, so that we raise no objection to using the Duo-Safety plates in milk heaters, in particular as regards their safety.