CONTINUOUS AND EARLY DETECTION OF TOXICITY IN INDUSTRIAL WASTE-WATER USING AN ONLINE RESPIRATION METER

Citation
Cw. Kim et al., CONTINUOUS AND EARLY DETECTION OF TOXICITY IN INDUSTRIAL WASTE-WATER USING AN ONLINE RESPIRATION METER, Water science and technology, 30(3), 1994, pp. 11-19
Citations number
9
Categorie Soggetti
Water Resources","Environmental Sciences","Engineering, Civil
ISSN journal
02731223
Volume
30
Issue
3
Year of publication
1994
Pages
11 - 19
Database
ISI
SICI code
0273-1223(1994)30:3<11:CAEDOT>2.0.ZU;2-D
Abstract
An on-line toxic detection system is introduced for early and continuo us observation of toxicity in an industrial wastewater treatment plant . The system consists of a contact chamber and an on-line respiration meter. If a raw wastewater sample is taken at the head of the wastewat er treatment plant, one can detect toxicity of the wastewater before i t reaches the aeration tank. For proper usage of this system a maximum respiration rate should be measured in the contact chamber. To apply this system on the petrochemical wastewater the Q(a)/Q(s) ratio should be maintained higher than 0.6 among other operating conditions requir ed When this system was tested under high and low pH, Co2+ inhibition, and recovered catalyst wastes addition, the system responded very sen sitively.