A COMPARISON OF 3 METHODS OF ESTIMATING DISPLACEMENT ON AN INSTRUMENTED SINGLE PUNCH MACHINE

Citation
A. Munozruiz et al., A COMPARISON OF 3 METHODS OF ESTIMATING DISPLACEMENT ON AN INSTRUMENTED SINGLE PUNCH MACHINE, Drug development and industrial pharmacy, 21(2), 1995, pp. 215-227
Citations number
18
Categorie Soggetti
Pharmacology & Pharmacy
ISSN journal
03639045
Volume
21
Issue
2
Year of publication
1995
Pages
215 - 227
Database
ISI
SICI code
0363-9045(1995)21:2<215:ACO3MO>2.0.ZU;2-C
Abstract
In this paper a determination of the possible sources of experimental errors of displacement measurements by an instrumented single-punch ma chine and their repercussion in compression parameters has been accomp lished. Also, elastic deformation of punches and other parts of the ma chine was evaluated using three different methods. One of these, based on the strain gauge response as measure of punch deformation it is pr oposed as a novel method to correct displacement measurements by instr umented machines.