Va. Mioli et al., BEHAVIOR OF BETA-2-MICROGLOBULIN (B2-M) SERUM LEVELS IN UREMIC PATIENTS, International journal of artificial organs, 17(11), 1994, pp. 576-580
This study was performed in 97 hemodialysis patients (85 on HD and 12
on CAPD) to investigate the possible correlation between B2-m and hemo
dialysis-related amyloidosis syndromes (HRA-S); differences in B2-m an
d HRA behavior between patients hemodialysed with cellulose and synthe
tic membranes were also included in the present study. Data indicate t
hat B2-m levels are not correlated with dialysis length or with the ty
pe of membrane used for the dialysis. On the contrary, in 16 patients
with the Carpal Tunnel Syndrome, a significant correlation was found b
etween the CTS, the dialysis length and the type of membrane (greater
incidence with cellulosic membranes).