ONE DROP FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF LEAD COMBINED WITH SOLVENT-EXTRACTION AFTER PRECONCENTRATION WITH CALCIUM-FLUORIDE
Citation
I. Kojima et S. Nomura, ONE DROP FLAME ATOMIC-ABSORPTION SPECTROMETRIC DETERMINATION OF LEAD COMBINED WITH SOLVENT-EXTRACTION AFTER PRECONCENTRATION WITH CALCIUM-FLUORIDE, Analytical sciences, 11(1), 1995, pp. 17-21
Categorie Soggetti
Chemistry Analytical
SICI code
0910-6340(1995)11:1<17:ODFASD>2.0.ZU;2-I
Abstract
After microwave acid digestion of botanical standards and the coprecip
itation of lead at pH > 1.0 as fluorides using calcium as a carrier, a
lead pyrrolidin-1-yldithioformate complex was extracted into a small
volume of chloroform. Direct nebulization of the chloroform extract in
to a fuel-lean air-acetylene flame gave a sensitive signal intensity.
The background-corrected signal intensity obtained by nebulizing 60 mu
l of the extract was 4.0 fold compared with that obtained by nebulizin
g 100 mul of an aqueous solution. The present method was successfully
applied to the determination of lead in the following botanical-certif
ied reference materials: National Institute of Standards and Technolog
y, Standard Reference Materials (NIST SRMs) 1571 Orchard Leaves, 1572
Citrus Leaves and 1573 Tomato Leaves. The results agreed well with the
certified values (reference values: 45+/-3, 13.3+/-2.4, 6.3+/-0.3; fo
und: 43.9+/-1.0, 13.0+/-0.1, 6.1+/-0.2 mug g-1, respectively).