DETERMINATION OF OXELADIN IN HUMAN PLASMA BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY

Citation
C. Lartiguemattei et al., DETERMINATION OF OXELADIN IN HUMAN PLASMA BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY, BMC. Biomedical chromatography, 9(1), 1995, pp. 32-35
Citations number
5
Categorie Soggetti
Chemistry Analytical","Pharmacology & Pharmacy",Biology
ISSN journal
02693879
Volume
9
Issue
1
Year of publication
1995
Pages
32 - 35
Database
ISI
SICI code
0269-3879(1995)9:1<32:DOOIHP>2.0.ZU;2-Y
Abstract
A capillary gas chromatographic method with mass-selective detection w as developed for the determination of oxeladin in human plasma. Plasma samples (1 mL) were alkalinized and extracted using 5 mt of hexane:is oamyl alcohol (99:1). The method was demonstrated to he sensitive (lim it of quantitation at 1 ng/mL), linear between 1 and 150 mg/mL, accura te and precise enough (mean error and mean coefficient of variation at the limit of quantitation were 2.3 and 13.3%, respectively) to suppor t pharmacokinetic evaluation of the drug at doses down to 30 mg.