GRINDING PRECISION AND ACCURACY OF FIT OF CEREC-2 CAD-CIM INLAYS

Citation
Wh. Mormann et J. Schug, GRINDING PRECISION AND ACCURACY OF FIT OF CEREC-2 CAD-CIM INLAYS, The Journal of the American Dental Association, 128(1), 1997, pp. 47-53
Citations number
41
Categorie Soggetti
Dentistry,Oral Surgery & Medicine
ISSN journal
00028177
Volume
128
Issue
1
Year of publication
1997
Pages
47 - 53
Database
ISI
SICI code
0002-8177(1997)128:1<47:GPAAOF>2.0.ZU;2-Q
Abstract
The authors conducted research to determine the grinding precision and accuracy of fit of ceramic inlays generated with the completely redes igned CEREC 2 computer-assisted design/computer-integrated manufacturi ng, or CAD-CIM, unit. They found that the grinding precision of the CE REC 2 unit was 2.4 times greater than that of CEREC 1. With CEREC 2, t he mean (+/- standard deviation) luting interfaces were 56 +/- 27 micr ometers, which is a 30 percent improvement in the accuracy of fit comp ared with that of CEREC 1.