The Fusion Aerosol Source Test (FAST) facility has been constructed to
produce and measure aerosol material from 316 SS under a wide range o
f accident conditions. Details of the design and fabrication of the fa
cility are presented including aerosol production and measurement equi
pment, effluent control, and data analysis. Preliminary testing has be
en completed and results from these preliminary tests are presented.