FAST ELECTROMAGNETIC GAS VALVE

Citation
Zg. Shen et al., FAST ELECTROMAGNETIC GAS VALVE, Measurement science & technology, 6(3), 1995, pp. 324-328
Citations number
12
Categorie Soggetti
Instument & Instrumentation",Engineering
ISSN journal
09570233
Volume
6
Issue
3
Year of publication
1995
Pages
324 - 328
Database
ISI
SICI code
0957-0233(1995)6:3<324:FEGV>2.0.ZU;2-8
Abstract
A new type of fast acting electromagnetic valve has been developed. Th e tests and analysis reveal that the repetitiveness of the valve is ex cellent; the maximum relative error of less than 2% persists for every fifty repeated tests. The working parameters of the valve can be adju sted in rather wide ranges, e.g. the gas filling is continuously adjus table from 5x10(-4) Pa m(3) to 0.5 Pa m(3), the opening time of the va lve ranges from 20 mu s to 800 mu s. The tests also demonstrate the lo ng life of the valve. The dynamic process of the valve is presented in detail. The theoretical calculations are found to be in good agreemen t with the experimental results.