AUTOMATIC REGISTRATION OF SPECT IMAGES AS AN ALTERNATIVE TO IMMOBILIZATION IN NEUROACTIVATION STUDIES

Citation
Dc. Barber et al., AUTOMATIC REGISTRATION OF SPECT IMAGES AS AN ALTERNATIVE TO IMMOBILIZATION IN NEUROACTIVATION STUDIES, Physics in medicine and biology, 40(3), 1995, pp. 449-463
Citations number
20
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
ISSN journal
00319155
Volume
40
Issue
3
Year of publication
1995
Pages
449 - 463
Database
ISI
SICI code
0031-9155(1995)40:3<449:AROSIA>2.0.ZU;2-5
Abstract
Subtraction of the two components (baseline and stimulation) of a neur oactivation study using Tc-99(m) HMPAO SPECT requires accurate registr ation of the two images. Immobilization of the subject during and betw een the two components of the study can prove difficult and degrades s ignal to noise ratio. The use of an automated image registration techn ique for registering the two components of the test can, even in the c ase where the subject is removed from the scanner, produce significant ly better registration than immobilization.