A SELECTIVE LIQUID-CHROMATOGRAPHY ASSAY FOR THE DETERMINATION OF D1-ALPHA-TOCOPHEROL ACETATE IN PLASMA SAMPLES

Citation
S. Torrado et al., A SELECTIVE LIQUID-CHROMATOGRAPHY ASSAY FOR THE DETERMINATION OF D1-ALPHA-TOCOPHEROL ACETATE IN PLASMA SAMPLES, Journal of liquid chromatography, 18(6), 1995, pp. 1251-1264
Citations number
13
Categorie Soggetti
Chemistry Analytical
ISSN journal
01483919
Volume
18
Issue
6
Year of publication
1995
Pages
1251 - 1264
Database
ISI
SICI code
0148-3919(1995)18:6<1251:ASLAFT>2.0.ZU;2-#
Abstract
A high-performance liquid chromatographic (HPLC) method for the assay of tocopherol and tocopherol acetate in biological samples is describe d. Results was presented for the linearity, sensitivity and reproducib ility. This HPLC method for tocopherol acetate was acceptable in terms of linearity, sensitivity and inter-day reproducibility and was conve nient for the routine analysis of plasma samples.