CHANGES IN THE CLINICAL AND INSTRUMENTAL PARAMETERS IN PATIENTS WITH MITRAL-STENOSIS FOLLOWING BALLOON CATHETER VALVULOPLASTY

Citation
Gm. Yakovlev et al., CHANGES IN THE CLINICAL AND INSTRUMENTAL PARAMETERS IN PATIENTS WITH MITRAL-STENOSIS FOLLOWING BALLOON CATHETER VALVULOPLASTY, Kliniceskaa medicina, 72(5), 1994, pp. 37-39
Citations number
12
Categorie Soggetti
Medicine, General & Internal
Journal title
ISSN journal
00232149
Volume
72
Issue
5
Year of publication
1994
Pages
37 - 39
Database
ISI
SICI code
0023-2149(1994)72:5<37:CITCAI>2.0.ZU;2-W
Abstract
The results of mitral valvuloplasty using a balloon catheter were pres ented for 104 patients with mitral stenosis. Instrumental measurements and clinical symptoms were evaluated before the operation, 6 and 12 m onths after it (62 and 42 patients, respectively). The balloon dilatat ion has increased mitral orifice from 120.5+/-5.8 to 333.88+/-7.45 mm( 2), transmitral diastolic pressure gradient decreased from 22+/-1 to 7 .91+/-0.6 mm Hg. All the patients benefited clinically: cough, blood s pitting, lower limb edemas, protodiastolic murmur disappeared, dyspnea noticeably reduced. NYHA functional class I-II was established in 85% of the patients. The highest effect was achieved in patients with iso lated mitral stenosis.