B. Schneider et al., MEASUREMENT OF FEMORAL TORSION AND TIBIAL TORSION USING MAGNETIC-RESONANCE-IMAGING (MRI), RoFo. Fortschritte auf dem Gebiete der Rontgenstrahlen und der neuenbildgebenden Verfahren, 162(3), 1995, pp. 229-231
Purpose: A new MRI method for the measurement of femoral torsion and t
ibial torsion is presented. Methods: Axial images were generated using
a standard gradient echo sequence (FLASH 2D). Otherwise measurement o
f femoral and tibial torsion was performed according to an established
CT method. Results: The torsion angles measured using MRI were in acc
ordance with the angles measured using the CT method. The MRI method w
as not more time-consuming than the CT method. Conclusion: In respect
of radiation exposure, MRI determination of femoral and tibial torsion
should be considered particularly in children and patients who have t
o undergo repeated torsion measurements.