A creep-thermal cycling system with a constant stress cam has been des
igned to be inexpensive and easily fabricated in order to identify the
creep and thermalcycling damage mechanisms in metal-matrix composites
(MMCs) with high ductility. The current system can be modified to be
a stress thermal cycling (or fatigue) system.