MOCK-UP OF THE FOCUSING UNDULATOR FOR THE SLAC X-RAY FEL PROJECT

Citation
Aa. Varfolomeev et al., MOCK-UP OF THE FOCUSING UNDULATOR FOR THE SLAC X-RAY FEL PROJECT, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 358(1-3), 1995, pp. 70-71
Citations number
7
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
358
Issue
1-3
Year of publication
1995
Pages
70 - 71
Database
ISI
SICI code
0168-9002(1995)358:1-3<70:MOTFUF>2.0.ZU;2-4
Abstract
A small prototype of the undulator requested for the SLAG X-ray FEL pr oject was designed and manufactured. Experimental results on the magne tic fields obtained with the five period model show that the hybrid sc heme using side magnet arrays is very promising. It can provide the sp ecified magnetic field profiles in a small area near the undulator axi s, focusing fields are easily adjustable, and the construction is comp act.