Nj. Medlicott et al., DETERMINATION OF SMALL SAMPLE VOLUMES IN THE ANALYSIS OF DRUGS AT SPECIFIC SITES IN THE ORAL CAVITY, Journal of Periodontal Research, 30(2), 1995, pp. 144-146
Two methods for the determination of sample volumes between 0.2 and 0.
6 mu l were compared by preparing standard curves for volumes over thi
s range. The first method used a Periotron and the second the sample m
ass. A linear model was fitted and 95% confidence limits for volumes e
stimated by each method were calculated. This showed that use of eithe
r the maximum Periotron reading or the sample mass allowed estimation
of volumes to within +/-0.056 mu l and +/-0.047 mu l respectively. It
is proposed that measurement of sample mass provides a simple and accu
rate method to determine sample volume when analysing drug concentrati
ons at specific sites in the oral cavity.