X-RAY-EXPOSURE OF RADIOLOGISTS AND STAFF IN INTERVENTIONAL RADIOLOGY

Citation
N. Meier et al., X-RAY-EXPOSURE OF RADIOLOGISTS AND STAFF IN INTERVENTIONAL RADIOLOGY, Radiologe, 35(3), 1995, pp. 152-155
Citations number
10
Categorie Soggetti
Radiology,Nuclear Medicine & Medical Imaging
Journal title
ISSN journal
0033832X
Volume
35
Issue
3
Year of publication
1995
Pages
152 - 155
Database
ISI
SICI code
0033-832X(1995)35:3<152:XORASI>2.0.ZU;2-Q
Abstract
The surface dose at five typical positions around the patient couch wa s measured during transjugular intrahepatic portosystemic stent shunt (TIPSS) interventions for retrospective calculation of staff dose. Add itionally, the surface dose was measured on three members of staff (tw o radiologists and one technician) by placing thermoluminescence (TL) dosimeters directly on the eyebrows, thyroid, sternum, gonads, hands, knees, and feet, The measured surface dose values and the TL dosimeter measurements are used for estimation of effective dose per examinatio n received by personnel. The effective dose for the radiologists is ca lculated to 25-35 mu Sv. The maximum number of examinations allowed pe r year is calculated on the basis of a given yearly dose limit, by loo king at organ dose and effective body dose.