DELAY MEASUREMENTS USING A SELF-PULSATING LASER WITH OPTOELECTRONIC FEEDBACK

Citation
Ag. Podoleanu et al., DELAY MEASUREMENTS USING A SELF-PULSATING LASER WITH OPTOELECTRONIC FEEDBACK, Measurement science & technology, 6(4), 1995, pp. 371-375
Citations number
8
Categorie Soggetti
Instument & Instrumentation",Engineering
ISSN journal
09570233
Volume
6
Issue
4
Year of publication
1995
Pages
371 - 375
Database
ISI
SICI code
0957-0233(1995)6:4<371:DMUASL>2.0.ZU;2-5
Abstract
The properties offered by including a self-pulsating laser in a feedba ck loop for distance and cable length measurements are investigated. A simple method for the measurement of distance, displacement and cable length based on the unique properties of a self-pulsating laser is re ported. Measuring the main frequency peak of the regenerative oscillat ions under the condition of high gain, 30 mu m accuracy could be attai ned for a range of 3 cm.